@paulinebellingmo

In calm_water_resistance.py within CalmWaterResistanceHollenbachBase._get_total_resistance_mean_minsaas some corrections are suggested:

  • Add appendage resistance
  • Do not convert velocity from m_per_s to knots when computing the roughness correction dc_f