# Netris CaaS Networking

This document describes how network traffic flows through the OSAC
infrastructure when using Netris as the network backend. It covers the
physical underlay (switches, softgates, uplinks), the logical overlay (VPCs,
NAT rules), and the packet-level path for each traffic direction.

## Netris Component Roles

The Netris fabric has three component types, each with a distinct role in the
data plane:

| Component | What it is | Data-plane role |
|-----------|-----------|-----------------|
| **Switch** (leaf/spine) | Physical network switch running a Netris agent | L2/L3 forwarding for all traffic (east-west and north-south), VXLAN encapsulation, EVPN, anycast gateway, VRF isolation, ACL enforcement. Does NOT perform NAT. |
| **SoftGate** | x86 server at the fabric edge running Netris gateway software | All NAT (SNAT/DNAT), L4 load balancing, BGP peering with upstream routers, default route injection into VPCs. The internet gateway. |
| **Controller** | Centralized management server | Pure control plane. Translates intent (VPC, NAT rule, server cluster) into device configs pushed to switches and softgates via gRPC. Not in the data path. |

## Physical Underlay

The physical fabric follows a spine-leaf Clos topology. SoftGates sit at the
top, connecting to the upstream router (internet) and the spine layer.
Servers connect to leaf switches via bonded VPC NICs for redundancy. The
Netris Controller manages all devices but is not in the data path.

```mermaid
%%{init: {'theme': 'dark', 'themeVariables': {'lineColor': '#ff9933'}, 'flowchart': {'defaultRenderer': 'elk'}}}%%
graph TB
internet((Internet))
upstream[Upstream Router]

sg1[SoftGate 1 - NAT / BGP]
sg2[SoftGate 2 - NAT / BGP]

subgraph spine [Spine Layer]
spine1[Spine 1]
spine2[Spine 2]
end

subgraph leaf [Leaf Layer - VXLAN / EVPN / VRF]
leaf1[Leaf 1]
leaf2[Leaf 2]
end

subgraph srv1 [Server 1]
bond1[Bond]
end

subgraph srv2 [Server 2]
bond2[Bond]
end

subgraph srv3 [Server 3]
bond3[Bond]
end

internet --- upstream
upstream --- sg1
upstream --- sg2
sg1 --- spine1
sg1 --- spine2
sg2 --- spine1
sg2 --- spine2
spine1 --- leaf1
spine1 --- leaf2
spine2 --- leaf1
spine2 --- leaf2
leaf1 --- bond1
leaf2 --- bond1
leaf1 --- bond2
leaf2 --- bond2
leaf1 --- bond3
leaf2 --- bond3
```

Each server has two VPC NICs bonded across both leaf switches. Spine
switches form a full mesh between all leafs. SoftGates peer with the
Copy link
Copy Markdown

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

⚠️ Potential issue | 🟡 Minor | ⚡ Quick win

Fix plural form of "leaf".

The standard plural of "leaf" is "leaves", not "leafs". This was flagged by the grammar checker.

📝 Proposed fix
-switches form a full mesh between all leafs. SoftGates peer with the
+switches form a full mesh between all leaves. SoftGates peer with the

As per coding guidelines, the static analysis tool LanguageTool flagged this as a spelling/grammar error.

📝 Committable suggestion

‼️ IMPORTANT
Carefully review the code before committing. Ensure that it accurately replaces the highlighted code, contains no missing lines, and has no issues with indentation. Thoroughly test & benchmark the code to ensure it meets the requirements.

Suggested change
switches form a full mesh between all leafs. SoftGates peer with the
switches form a full mesh between all leaves. SoftGates peer with the
🧰 Tools
🪛 LanguageTool

[grammar] ~77-~77: Ensure spelling is correct
Context: ...e switches form a full mesh between all leafs. SoftGates peer with the upstream route...

(QB_NEW_EN_ORTHOGRAPHY_ERROR_IDS_1)

🤖 Prompt for AI Agents
Verify each finding against current code. Fix only still-valid issues, skip the
rest with a brief reason, keep changes minimal, and validate.

In `@features/netris-caas-networking.md` at line 77, The sentence contains the
incorrect plural "leafs" in the phrase "switches form a full mesh between all
leafs"; update that phrase to use the correct plural "leaves" (i.e., "switches
form a full mesh between all leaves") to fix the grammar in the document.

upstream router via BGP, advertising public IPs (/32) for DNAT and receiving
default routes for outbound traffic.

## Logical Overlay

The overlay runs on top of the physical fabric using VXLAN tunnels and VRFs
on the leaf switches. Each hosted cluster gets its own VPC (isolated VRF).
The SoftGate is the gateway between VPCs and the internet.

```mermaid
%%{init: {'theme': 'dark', 'themeVariables': {'lineColor': '#ff9933'}, 'flowchart': {'defaultRenderer': 'elk'}}}%%
graph TB
internet((Internet))
Copy link
Copy Markdown
Member

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Just looking at the diagram, it seems unexpected that worker nodes communicate with their hosted control plane through the "Internet".

Copy link
Copy Markdown
Contributor Author

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

via the internet here means they need to go through the gateway, its is not actually leaving to the internet. I agree it has pros and cons, this was the initial implementation which was consistent with what was done in MOC

Copy link
Copy Markdown
Member

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

WDYT about updating the diagram to clarify? I think a lot of readers could get the wrong impression that we are sending traffic to the internet.


mgmt_snat[Mgmt SNAT]
mgmt_api_dnat[Mgmt API DNAT :6443]
hosted_api_dnat[Hosted Cluster API DNAT :6443]
cluster_snat[Cluster SNAT]
ingress_dnat[Hosted Cluster Ingress DNAT :80/:443]

subgraph mgmt_vpc [Management VPC]
mgmt_gw[Anycast Gateway]
mgmt_metallb[MetalLB VIP]

subgraph mgmt_cluster [Management Cluster]
mce[MCE]
hypershift[HyperShift]
aap[AAP]
mgmt_metallb_op[MetalLB Operator]
storage_op[Storage Operator]
hosted_apiserver[Hosted kube-apiserver]
end

mgmt_apiserver_lb[Mgmt kube-apiserver]
end

subgraph cluster_vpc [Cluster VPC - 192.168.101.0/24]
gw[Anycast Gateway 192.168.101.1]
metallb[MetalLB VIP 192.168.101.28]
node1[Worker 1 - 192.168.101.2]
node2[Worker 2 - 192.168.101.3]
node3[Worker 3 - 192.168.101.4]
end

internet --- mgmt_snat
internet --- mgmt_api_dnat
internet --- hosted_api_dnat
internet --- cluster_snat
internet --- ingress_dnat

mgmt_snat --- mgmt_gw
mgmt_api_dnat --- mgmt_apiserver_lb
hosted_api_dnat --- mgmt_metallb
mgmt_metallb --- hosted_apiserver
mgmt_gw --- mgmt_cluster

ingress_dnat --- metallb
cluster_snat --- gw
gw --- node1
gw --- node2
gw --- node3
metallb --- node1
metallb --- node2
metallb --- node3
```

The management VPC and each cluster VPC are separate VRFs on the same
physical switches. The SoftGate bridges them to the internet:

- **SNAT** on both VPCs gives their nodes outbound internet access
- **API DNAT** on the management VPC routes `:6443` to the kube-apiserver LB
on the hosting cluster (because HyperShift runs the apiserver there)
- **Ingress DNAT** on the cluster VPC routes `:80/:443` to the MetalLB VIP
on the worker nodes (because the ingress controller runs there)

Note the anycast gateway and MetalLB VIP serve different roles in the
cluster VPC. The **anycast gateway** (`192.168.101.1`) is the default route
for egress — worker nodes send all outbound traffic through it, and the
leaf switch forwards it to the SoftGate for SNAT. The **MetalLB VIP**
(`192.168.101.28`) handles ingress — it is an L2 address advertised via ARP
directly on a worker node's NIC, so DNAT'd packets from the SoftGate reach
it without passing through the gateway.

### How the components interact

**Switches** (spine and leaf layers) carry all traffic through the fabric —
both east-west (server-to-server) and north-south (server-to-SoftGate-to-internet).
They use VXLAN overlays with BGP EVPN for MAC/IP learning. Each VPC maps to
a VRF on the switches, providing routing table isolation. V-Nets within a
VPC get unique VXLAN Network Identifiers (VNIs). Leaf switches also run
anycast gateways — every leaf hosting a VPC advertises the same gateway IP
and MAC, so traffic is routed at the nearest leaf without tromboning.

**SoftGates** connect to the leaf switches and to the upstream router. They
are the only path to the internet. When a NAT rule is created for a VPC, the
SoftGate injects a default route (`0.0.0.0/0`) into that VPC's VRF on the
switches, steering all outbound traffic through itself. SoftGates also
advertise public IPs (DNAT destinations) as /32 routes to the upstream
router via BGP, attracting inbound traffic. All NAT translation happens on
the SoftGate — switches never rewrite packet headers.

**Controller** pushes configuration to switches and SoftGates via gRPC. If
the controller goes down, devices continue forwarding with their last-known
config — only new changes stop.

## Overlay: VPCs and Per-Cluster Resources

Each hosted cluster operates across two VPCs and a management network:

| Plane | Purpose | Scope |
|-------|---------|-------|
| **Management VPC** | Hosts the hosting cluster control plane (MCE, HyperShift, kube-apiserver pods). Shared across all hosted clusters. | One per site |
| **Per-cluster VPC** | Dedicated L3 network for each hosted cluster's worker nodes. Auto-created when a Netris server cluster is provisioned. Maps to a VRF + VNI on the switches. | One per hosted cluster |
| **Management network** | Out-of-band access to bare-metal servers via their management NIC (DHCP). Used for SSH-based NMState configuration. Not managed by Netris. | Flat, site-wide |

### Per-cluster resources created by Netris

| Resource | Name | Where it lives |
|----------|------|----------------|
| Server cluster | `<cluster-name>` | Controller config, pushed to switches |
| VPC (VRF + VNI) | `<cluster-name>` (auto-created) | Switch VRF tables |
| Anycast gateway | `192.168.101.1` on every leaf with cluster members | Switch SVIs |
| SNAT rule | `<cluster-name>-snat` | SoftGate NAT table |
| API DNAT rule | `<cluster-name>-api-dnat` | SoftGate NAT table |
| Ingress HTTP DNAT | `<cluster-name>-ingress-http-dnat` | SoftGate NAT table |
| Ingress HTTPS DNAT | `<cluster-name>-ingress-https-dnat` | SoftGate NAT table |
| DNS A records | `api.`, `api-int.`, `*.apps.` | Route53 |

Each cluster consumes **3 public IPs** from the Netris IPAM NAT pool: 1 for
SNAT, 1 for the API DNAT, and 1 for the ingress DNAT.

### Bare-metal server NIC layout

Each worker node has two types of network interfaces:

| Interface | Example | IP assignment | Connected to |
|-----------|---------|---------------|-------------|
| Management NIC | `eno1` | DHCP (unchanged from PXE boot) | Management network (not Netris-managed) |
| VPC NIC(s) | `ens1f0np0`, `ens1f1np1` | Static (first NIC only) | Leaf switch port (Netris-managed, VXLAN access port) |

The routing table on each node:

| Destination | Gateway | Interface | Metric | Effect |
|-------------|---------|-----------|--------|--------|
| `0.0.0.0/0` (default) | VPC anycast gateway (`192.168.101.1`) | VPC NIC | 50 | All data traffic goes through leaf switch into VPC |
| Management CIDR | Management gateway | Mgmt NIC | 100 | Bastion/controller traffic stays on mgmt network |

## Management Plane: NMState Configuration via SSH

Network configuration on live servers is applied through the management
network, not the data plane:

```
Ansible controller
-> SSH to bastion (management network)
-> SSH to server mgmt NIC (eno1, DHCP IP)
Copy link
Copy Markdown
Member

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Is this mgmt NIC the BMC or equivalent? I'm trying to understand how such an ssh session is getting access to the node's OS in order to run nmstatectl there.

Copy link
Copy Markdown
Contributor Author

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

this is NIC which assigned IP via mgmt DHCP. The relevant keys are provided as secrets.

Copy link
Copy Markdown
Member

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Is this a NIC that's part of the normal system, and managed by the host OS? Or is this NIC part of the BMC that would often be accessed by redfish?

-> nmstatectl apply: configures VPC NICs with static IPs and routes
Copy link
Copy Markdown
Member

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Is it possible / reasonable to use the nmstate operator instead?

Copy link
Copy Markdown
Contributor Author

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

I am not sue you can use nmstate operator for non OCP nodes

```
Comment on lines +230 to +235
Copy link
Copy Markdown

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

⚠️ Potential issue | 🟡 Minor | ⚡ Quick win

Add language specifier to code block.

The fenced code block should specify a language for proper syntax highlighting and to satisfy markdown linting rules. Since this is ASCII art showing a connection flow, use text as the language specifier.

📝 Proposed fix
-```
+```text
 Ansible controller
   -> SSH to bastion (management network)
     -> SSH to server mgmt NIC (eno1, DHCP IP)

As per coding guidelines, markdownlint flagged this as MD040 (fenced-code-language).

🧰 Tools
🪛 markdownlint-cli2 (0.22.1)

[warning] 230-230: Fenced code blocks should have a language specified

(MD040, fenced-code-language)

🤖 Prompt for AI Agents
Verify each finding against current code. Fix only still-valid issues, skip the
rest with a brief reason, keep changes minimal, and validate.

In `@features/netris-caas-networking.md` around lines 230 - 235, The fenced code
block containing the ASCII connection flow ("Ansible controller -> SSH to
bastion -> SSH to server mgmt NIC -> nmstatectl apply...") lacks a language
specifier and triggers markdownlint MD040; fix it by changing the opening
backticks to include the language `text` (i.e., replace ``` with ```text) so the
block reads as a text-coded fence and preserves the ASCII art formatting.


This two-hop path ensures the management connection is never disrupted by
the VPC reconfiguration it triggers — the management NIC and routes are left
untouched.